Medical Grade Gloves
Kimberly-Clark Sterling™ Nitrile
Sterling nitrile gloves provide worry free comfort. They give the user the protection of nitrile with the sensitivity of latex. Perfect for laboratory environments.
- Textured fingertips
- 3.5 mil. thickness
Sterling™ is a Trademark of Kimberly-Clark Worldwide, Inc.

Style | Description | Size | Pack | Qty | |
---|---|---|---|---|---|
5508X | 9.5" ambi | 150/box, 10 boxes/case (XL 140/box) | |||
531XX | 12" ambi | 100/box, 10 boxes/case |
Specifications
Code | Size | Palm Width* (mm) | Length* (mm) | Quantity |
---|---|---|---|---|
55085 | XS | 70 | 242 | 150 gloves/box/10 boxes/case |
55086 | S | 80 | 242 | 150 gloves/box/10 boxes/case |
55087 | M | 95 | 242 | 150 gloves/box/10 boxes/case |
55088 | L | 110 | 242 | 150 gloves/box/10 boxes/case |
55089 | XL | 120 | 242 | 150 gloves/box/10 boxes/case |
*As measured by ASTM D 6319; 2.5 AQL1
General Description
Light Gray nitrile, powder free, exam, non-sterile, textured fingertips, ambidextrous gloves, beaded cuff, and single or double chlorination, 9.5"
Physical Property | Unit | Upper Limit | Test Method (1.5 AQL) |
---|---|---|---|
Watertightness | NA | Pass | ASTD D 5151 |
Residual Powder | mg/glove | 2 | ASTD D 6124 |
Thickness | Nominal | Nominal | Test Method (1.0 AQl) |
Middle Finger | 3.54 mil | 0.09 mm | ASTM D 6319 |
Palm | 3.15 mil | 0.08 mm | ASTM D 6319 |
Cuff | 2.36 mil | 0.06 mm | ASTM D 6319 |
Property | Tensile Strength | Ultimate Elongation | |
Before Aging | 42.0 Mpa | 650% | |
After Aging | 38.0 Mpa | 550% | |
Test Method (2.5 AQL) | ASTM D 412 ASTM D 6319 ASTM D 573 | ASTM D 412 ASTM D 573 ASTM D 6319 |
1AQL levels defined according to ISO 2859-1 (current edition) Sampling Procedures for Inspection by Attributes.