Wipers
Anticon 100®
Anticon 100 wipes are made from 100% continuous filament polyester with a double-knit interlock construction. The clean cut edges exhibit low particle and fiber counts to minimize contamination. Using patented textile technology, Anticon 100 achieves superior capacity with a quick sorption rate.
- Lowest fibers in a cut edge reduces risk of contamination
- High sorptive capacity decreases wipes required
- Manufactured from 100% continuous filament polyester and specially processed for superior cleanliness and sorbency
- Laundered and packaged in an ISO Class 4 cleanroom.
- Tested in accordance with the IEST Recommend Practices for the Evaluation of Wiping Materials for Critical Environments
- Available in 9" x 9" and 12" x 12" sizes
- Available in a 9” x 9” sterile version
- Offered in bulk and stacked packaging
Style | Description | Size | Pack | Qty | |
---|---|---|---|---|---|
495352 | Standard Weight | 9 in.x9 in.: 150/bag/ 8 bags/case 12 in.x12 in.: 100/bag, 4 bags/case |
|||
492222 | Heavy Weight | 9 in.x9 in.: 150/bag/ 8 bags/case 12 in.x12 in.: 100/bag, 4 bags/case |
|||
492226 | Sterile | 9 in.x9 in. (492226-939) | 20 wipes/inner bag, 5 inner bags/outer bag; 8 outer bags/case |
Specifications
Technical Data
Standard Weight | Heavy Weight | Sterile | Test Methods | |
---|---|---|---|---|
Wipe Material | 100% Polyester | 100% Polyester | 100% Polyester | |
Wipe Construction | Interlock Knit | Interlock Knit, no run | Interlock Knit, no run | |
Attribute; (units) | Value | Test Method | ||
Basis weight; nominal (g/m2) | 120 | 140 | 140 | Contec Method |
Sorbency in water Intrinsic; (mL/g) Extrinisic;(mL/m2) | 2.87 339 | 3.20 455 | 3.20 455 | IEST-RP-CC004.3, Sect. 8.1 IEST-RP-CC004.3, Sect. 8.1 |
Sorptive rate; (seconds) | <1 | <1 | <1 | IEST-RP-CC004.3, Sec. 8.2 |
Non-volative residue, NVR In deionized water; (g/m2) In isopropanol; (g/m2) | 0.004 0.008 | 0.013 0.005 | 0.013 0.005 | IEST-RP-CC004.3, Sec. 7.1.1 |
Specific ions Sodium; (ppm) Chloride; (ppm) | 0.184 0.030 | 0.022 0.007 | 0.007 0.005 | IEST-RP-CC004.3, Sec. 7.2.2 |
Particles, (Biaxial Shake) P ≥ 0.5µm (x106/m2) | 3.97 | 5.69 | 5.69 | IEST-RP-CC004.3, Sec. 6.1.3 |
Fibers > 100µm; (x103/m2) | 1.558 | 3.15 | 3.15 | IEST-RP-CC004.3, sec. 6.2.2 |